Barrier-Free Door Requirements in Ontario

Key points

  • The Ontario Building Code sets the door rules for a barrier-free path of travel.
  • The usual sticking points are clear width, opening force, hardware and where a power operator is needed.
  • The figures below come from the 2024 Code. Older buildings were built to earlier editions, so check before you plan work.

Barrier-free door rules are specific, and most of them can be checked with a tape measure and a force gauge. This guide covers the requirements property managers ask about most often. It is a summary, not a substitute for the Code or for advice on your building.

The main numbers

RequirementWhat the Code calls for
Clear widthAt least 850 mm with the door open
Door hardwareOperable with a closed fist, mounted 900 to 1,100 mm above the floor
Opening force, no power operatorNo more than 38 N on exterior doors and 22 N on interior doors
Closing time, interior doorsAt least 3 seconds from 70 degrees open to 75 mm from closed
Space beside the latch600 mm on the pull side and 300 mm on the push side, unless a power operator is fitted

Where a power door operator is required

The Code calls for power operators on doors in a barrier-free path through a barrier-free entrance, on vestibule doors leading into the building, and on doors serving a required barrier-free public washroom. There are exceptions, and the details depend on how the building is used.

Operator controls

  • At least 150 mm across if round, or 50 by 100 mm if rectangular.
  • Operable with a closed fist.
  • Centred 900 to 1,100 mm above the floor, or a vertical bar that reaches from no higher than 200 mm to at least 900 mm.
  • Set 600 to 1,500 mm beyond the door swing where the door opens toward the control.
  • Marked with the International Symbol of Access.

What goes wrong in existing buildings

  • A closer set too strong, so the door fails the opening force limit. See our guide to door closer problems.
  • Push buttons blocked by furniture, planters or displays.
  • An operator that has been switched off after a fault and never repaired.
  • Round knobs or thumb turns left on doors that need lever hardware.
  • A sensor that does not pick up a person in a wheelchair.

The Building Code and the AODA

The measurements above come from the Ontario Building Code, which applies when a building is built or renovated. The Accessibility for Ontarians with Disabilities Act is a separate law that sets accessibility standards for organizations.

Other provinces use their own codes, most of them based on the National Building Code of Canada, and the figures differ. Confirm the requirements with your building official or code consultant before starting work.

Source: Ontario Building Code 2024, Division B, Article 3.8.3.3.

We install and service automatic and barrier-free door operators across Canada.